Elevator Repair at Fisher House Bldg 425

Veterans Affairs, Department of › 250-network Contract Office 10 (36c250)

This sources sought notice is for the repair of an elevator at the Fisher House (Bldg 425) located at the Dayton VA Medical Center, which is currently out of service due to lightning damage. The work involves repairing the I/O board and replacing the CPU board of the elevator.Our analysis

Trade
Other building equipment
NAICS 238290
Set-aside
SDVOSBC
Est. value
Not stated
Timeline
Today Posted Fri Jul 10 Site visit Wed Jul 15 Deadline Tue Jul 21
Dayton, OH Open in Google Maps

Sign in to unlock the full opportunity

Project specs, incumbent and pricing intel, compliance requirements, past performance criteria, submission rules, and the full strategy guide. Sign in for 15 free full views every month.

Sign in
Bid pass Locked
Available on Professional Win likelihood, gaps, and headroom.
Competitors
--
Gaps
--
Max
--
Updated
--
Upgrade required
Contracting Officer
Brian Rosciszewski
Brian.Rosciszewski@VA.gov
9372686511

Job alerts

Email and text alerts when contracts like this one post.

NAICS 238290 · within 50 mi of Dayton, OH
Sign up
View on SAM.gov
Solicitation 36C25026Q0673 · closes Tuesday, July 21, 2026 at 4:00 PM BST. Items marked Our analysis are our read of the notice. Not stated means we didn’t find it. Verify on SAM.gov.
An active SAM.gov registration is required to bid.

Official SAM.gov record

Verify on SAM.gov

Everything SAM publishes on this notice, on one page.

Full description
THIS IS A SOURCES SOUGHT NOTICE: This announcement seeks information from industry to assist with identifying sources of repair for an elevator at the Dayton VAMC 4100 W. 3rd St, Dayton OH 45428. The purpose of this notice is to gain knowledge of interest and qualifications of elevator repair businesses. BACKGROUND. The only elevator servicing the two-story Fisher House (Bldg 425) at Dayton VAMC is not serviceable. It was damaged during a lightning storm. The elevator was manufactured by OTIS and is identified as H25701. The elevator was evaluated by an OTIS certified technician and two defects were noted: An I/O board was damaged and cannot be replaced, it must be repaired. The CPU is damaged and must be replaced. Contractor must confirm discrepancies and troubleshoot, if needed, to return the elevator to service. SCOPE Provide all labor, materials, and services necessary to facilitate the repair of the damaged I/O board, including packaging and shipment to an authorized repair facility. Replacement I/O boards are obsolete and unavailable; therefore, repair is required. Furnish and install one (1) new CPU board. Upon return and installation of the repaired I/O board and the new CPU board, perform all adjustments required to restore proper system functionality. All materials furnished and all work performed shall comply with the ASME A17.1 Safety Code for Elevators and Escalators. Upon completion, adjust the elevator for proper operation and conduct a full fire recall test...
Notice ID
4aa8ef83ac124cc0a91e00b0d4a20d69
Solicitation number
36C25026Q0673
Product service code (PSC)
Z1AZ
NAICS code
238290
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
Posted
Jul 10, 2026
Inactive after
Aug 05, 2026
Documents · 4 from SAM.gov

Files open on sam.gov. Generic labels are shown because the notice payload does not include original filenames.